<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-18 21-47-34
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
107.80 MHz 5/5, 53 dBuV P2 SR
Pilot RDS Phase Difference
7.3 kHz 5.7 kHz 0 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
14 kHz 26 kHz 19066 0,0420
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-5,9 dBr -3,19 dBr -1,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"P2 SR " E402 14 (Classics) 0 1 1 9 20:47, 18.12.2024
RT
"Konsert i P2 : Barockmusik med Anna Fusek och La Misticanza "
AF EON
91.7, 93.6, 94.5, 97.5 MHz E203, E224, E201
FM Scope Max at: 26 kHz MIN: 14 kHz % above 76 kHz: 0,0420 Acquired: 2024/12/18 21.46.30 Total samples: 19066 Equivalent time: 0:15:53 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: -1,0 dBr MIN: -5,9 dBr AVE: -3,19 dBr % above 12,2 dBr: 0,0 Last value: -4,0 dBr (2024/12/18 21.46.29) 21.32 21.34 21.36 21.38 21.40 21.42 21.44 21.46 0 50 100 Dev. MAX [kHz] -6 -4 -2 0 Pm [dBr]